Oxidising Solids tests mixtures of a reference oxidiser / cellulose and mixtures of the substance and cellulose.
Air Over Layer is conducted primarily for the purposes of transportation. Mixtures of a reference oxidiser (potassium bromate) / cellulose (fuel) and mixtures of the substance and cellulose (fuel) to be tested are prepared in specified ratios. Using a conical funnel the mixtures are formed into a truncated conical pile, covering a looped ignition wire resting on the low heat conducting plate.