How to conduct cable entry test
Fortunately, there are already standards for the quality of the cable itself in the standards of the wiring industry, such as TIA568B and ISO11801. After the customer completes the aerial bundled cable b231 standard selection, several 100m-long cables are selected for random testing according to a certain proportion of the cables sent by the engineering side. Due to the relatively large link density and total number of data centers, products purchased in batches are usually warehousing random inspections in most cases.
The sampling test ratio ranges from 2% to 20%. This has a lot to do with the total quantity of purchased products, Party A’s contract inspection ratio agreement and Party A’s attention to product quality. Of course, the customer is doing cable testing and must Use a test instrument that can support the aerial bundled cable (abc) b231 test standard in TIA568B, such as "DTX1800 cable analyzer" + "cable test adapter "LABA" pair + DTX-REFMOD module, after selecting a 100m twisted pair, you can complete the following steps Cable test before installation.
(1) Equipment calibration. Use the calibration module that comes with the instrument to calibrate the host and remote to eliminate errors between the test instruments.
(2) Connect the dedicated cable test adapter. Insert the LABAMN module on the host and remote respectively.
(3) Connect the abc cable under test
(4) Select the test standard. Select the dedicated test standard dedicated to twisted pair in the host, take 6A line as an example, select TIACat.6Acable100m(LA).
(5) Start the test. The instrument automatically completes all test items in accordance with the standard. Check the test results after 9 seconds to see if the twisted pair is qualified.
(6) Generate test reports. Because DTX series instruments support digital signal processing technology, through the inverse Fourier transform and transformation, the frequency domain signal is converted into time domain signal. After removing the strong interference signal at both ends of the 100m line from the time domain, it is converted into frequency domain curve again. . Thus, the standard test was accurately completed to identify the performance of the cable.